Dampers

Aras Power Systems designs and supplies flue-gas dampers — butterfly, louver, diverter, guillotine, shut-off and poppet types — for flow control and isolation in power-plant and industrial exhaust systems. Dampers are engineered for duct sizes from 0.3 m to 10 m and gas temperatures up to 650 °C, with seal-air guillotine and double-blade designs reaching up to 100% sealing efficiency for man-safe isolation.

Codes & standards

Aras Power Systems designs flue-gas dampers to the client-nominated code basis, combining international standards with project-specific operating, safety and documentation requirements.

  • ASME
  • EN 1090 / EN 1993
  • AMCA leakage class
  • ASME IX
  • ISO 12944

Our Services

Our engineering and supply scope is structured to deliver safe, efficient and project-specific equipment from concept design through fabrication, site support and documentation.

Design compliance

  • ASME and EN standards: ensuring that damper designs meet the project’s mechanical, structural and fabrication requirements.
  • Diverse damper types: engineering butterfly, louver, shut-off, diverter, guillotine and poppet dampers for specific flow-control and isolation duties.

Computational Fluid Dynamics (CFD)

  • Flow analysis: reviewing gas-flow distribution and pressure drop across damper blades and frames.
  • Operational efficiency: optimising on/off and modulating operation to maintain controlled flow with minimum energy loss.

Finite Element Analysis (FEA)

  • Structural integrity: verifying frames, shafts, blades and supports under temperature, pressure and actuation loads.
  • Temperature considerations: checking deformation risks and thermal expansion in hot-gas service.

High-temperature design

  • Material and coating selection: selecting carbon steel, stainless steel and coating systems for the process environment.
  • Thermal expansion: designing clearances and seals to prevent warping, sticking and leakage.

Actuation systems

  • Actuation mechanisms: integrating electric, pneumatic, hydraulic or manual drives.
  • Control integration: providing fail-open/fail-close logic, position feedback and plant DCS interface where required.

Documentation and quality assurance

  • Technical documentation: providing CAD drawings, specifications, actuator data and installation guidelines.
  • Testing and inspection: defining leakage, functional, dimensional, welding and coating controls.

Technical specification

TypesButterfly, louver, diverter, guillotine, shut-off, poppet
Duct size0.3 – 10 m, round or rectangular
Design temperatureUp to 650 °C, higher with lining/cooling and material upgrades
Sealing efficiencyUp to 100% with seal-air guillotine or double-blade designs
ActuationElectric, pneumatic, hydraulic, manual; fail-safe options
MaterialsCS S355/A36; SS 304/316/321; weathering steel

All ranges are a configurable engineering design envelope, finalised against project-specific data and applicable codes.

Applications

  • GT combined-cycle bypass and diverter systems
  • HRSG inlet/outlet isolation
  • Flue-gas desulphurisation ducting
  • Industrial exhaust and process-gas systems

Frequently asked questions

What sealing efficiency can your dampers achieve?

Seal-air guillotine and double-blade dampers can reach up to 100% sealing efficiency for man-safe positive isolation. Final sealing class is defined and verified according to project requirements.

What is the difference between a diverter and a guillotine damper?

A diverter damper routes gas between paths such as HRSG and bypass stack, while a guillotine damper provides positive isolation for safe downstream maintenance.

Which actuation options do you offer?

Electric, pneumatic, hydraulic and manual actuation can be supplied, including fail-open or fail-close configurations and DCS feedback signals.

What temperatures can the dampers handle?

Standard designs cover hot-gas service up to 650 °C, with higher temperatures handled through refractory lining, cooling arrangements or material upgrades.

Request engineering & a budget

Send your process data, site conditions and code basis, and the Aras engineering team will respond with a tailored concept and budget.

info@araspowersystems.com · +90 312 504 20 26 · +90 530 427 39 44