Heat Exchangers
Aras Power Systems designs shell-and-tube, air-cooled and plate heat exchangers to ASME BPVC Section VIII, TEMA and API 660/661/662, optimising thermal and mechanical design together for efficiency and fouling resistance. Units are engineered for vacuum-to-high-pressure service and temperatures from cryogenic to about 600 °C, with materials from carbon steel to duplex, titanium and copper alloys, and delivered from design through fabrication, erection, field testing and after-sales support.
Codes & standards
Aras Power Systems designs heat exchangers to the client-nominated code basis, combining international standards with project-specific operating, safety and documentation requirements.
- ASME BPVC Sec. VIII
- TEMA R/C/B
- API 660 / 661 / 662
- PED / EN 13445
- ASME IX
Our Services
Our engineering and supply scope is structured to deliver safe, efficient and project-specific equipment from concept design through fabrication, site support and documentation.
Design compliance
- International standards: designing heat exchangers in compliance with ASME, TEMA, API, PED and EN requirements.
- Custom design solutions: tailoring thermal duty, mechanical configuration, nozzle orientation and maintainability to the project.
Thermal and mechanical design
- Thermal performance: sizing heat-transfer area, pressure drop and fouling margins for the required duty.
- Mechanical integrity: integrating shell, tubesheet, channel, bundle and support design according to pressure and temperature requirements.
Structural analysis and optimisation
- FEA verification: validating critical components under pressure, thermal gradients and external loads.
- Performance optimisation: balancing efficiency, fouling resistance, pressure drop and maintenance access.
Manufacturing and fabrication
- Shop fabrication: fabricating exchanger components in controlled environments with traceable materials and welding procedures.
- Materials engineering: selecting carbon steel, stainless steel, duplex, titanium or copper alloys based on media compatibility.
Site erection and commissioning
- On-site assembly: supporting installation, alignment and tie-in of heat-exchanger packages.
- Field testing: supporting hydrostatic tests, leak checks and commissioning verification.
After-sales and maintenance support
- Operational support: providing performance review and troubleshooting after start-up.
- Maintenance strategies: supporting cleaning, inspection and lifecycle planning to sustain rated performance.
Technical specification
| Types | Shell-and-tube (TEMA), air-cooled fin-fan, plate heat exchangers |
|---|---|
| Design pressure | Vacuum to high pressure according to ASME VIII |
| Design temperature | Cryogenic to approximately 600 °C |
| Materials | Carbon steel, low-alloy steel, stainless steel, duplex, titanium, copper alloys |
| Testing | RT/UT, hydrostatic, tube-to-tubesheet testing, PMI as required |
All ranges are a configurable engineering design envelope, finalised against project-specific data and applicable codes.
Applications
- Lube-oil and fuel-oil cooling
- Feedwater and condensate heating
- Closed-loop equipment cooling
- General process heat transfer
Frequently asked questions
Which codes and standards do you design heat exchangers to?
Shell-and-tube units follow ASME BPVC Section VIII and TEMA classes R/C/B, with API 660/661/662 and PED/EN 13445 applied as required by the project.
What materials can you supply?
Carbon steel, low-alloy steel, stainless steel, duplex, titanium and copper alloys are selected according to thermal duty, pressure and fouling/corrosion service.
Do you provide after-sales support?
Yes. Aras provides commissioning, operational support and maintenance strategies to sustain rated performance and extend exchanger service life.
Request engineering & a budget
Send your process data, site conditions and code basis, and the Aras engineering team will respond with a tailored concept and budget.
info@araspowersystems.com · +90 312 504 20 26 · +90 530 427 39 44